Engineered to provide best-in-class pushability to help in crossing the lesion1
Over-the-wire design contributes to ease of guidewire exchange during procedures3
Engineered for maximum pushability5
The longest 0.018” Rapid Exchange (RX) PTA Balloon designed for use in radial to peripheral procedures1
R2P Crosstella RX 200cm showed greater crossability than Pacific Plus OTW 180cm and even Ultraverse RX 014 200cm by radial approach
RESULTS OF PUSHABILITY*
R2P Crosstella RX 200cm showed greater pushability than Pacific Plus OTW 180 cm by radial approach
Max. Input: R2P Crosstella RX 2.0N, Pacific Plus OTW 1.0N
Sample number: R2P Crosstella RX n=10, Pacific Plus OTW n=5
*Data on File
RESULT OF CROSSABILITY*
R2P Crosstella RX 200cm showed greater crossability than Pacific Plus OTW 180cm and even Ultraverse RX 014 200cm by radial approach
Sample number: R2P Crosstella RX n=10, Pacific Plus OTW and Ultraverse n=5
1Data on File REF: 00418
CROSSTELLA® OTW PTA Balloon Dilatation Catheter showed better pushability results*
*Tested against select leading competitors
1Data on File REF: 00418
Sample size: Terumo balloons n=10; Competitors n=5; 5 mm x 40 mm balloons
CROSSTELLA® RX PTA Balloon Dilatation Catheter demonstrated excellent crossability when tested against a leading competitor*
Sample size: Terumo balloons n=10; Competitors n=5; 5 mm x 40 mm balloons
CROSSTELLA® RX PTA Balloon Dilatation Catheter showed better pushability results*
Sample size: Terumo balloons n=10; Competitors n=5; 6mm x 200mm CROSSTELLA® RX balloons, 6mm x 220mm Sterling™ Monorail™ balloons (closest comparable size)
CROSSTELLA® RX PTA Balloon Dilatation Catheter provided the lowest deflation time results*
| Product Code | Description |
| BD-Q20040ER | 200 cm, 4 Fr, 2 mm x 40 mm |
| BD-Q20100ER | 200 cm, 4 Fr, 2 mm x 100 mm |
| BD-Q20150ER | 200 cm, 4 Fr, 2 mm x 150 mm |
| BD-Q20200ER | 200 cm, 4 Fr, 2 mm x 200 mm |
| BD-Q30040ER | 200 cm, 4 Fr, 3 mm x 40 mm |
| BD-Q30100ER | 200 cm, 4 Fr, 3 mm x 100 mm |
| BD-Q30150ER | 200 cm, 4 Fr, 3 mm x 150 mm |
| BD-Q30200ER | 200 cm, 4 Fr, 3 mm x 200 mm |
| BD-Q40040ER | 200 cm, 4 Fr, 4 mm x 40 mm |
| BD-Q40100ER | 200 cm, 4 Fr, 4 mm x 100 mm |
| BD-Q40150ER | 200 cm, 4 Fr, 4 mm x 150 mm |
| BD-Q40200ER | 200 cm, 4 Fr, 4 mm x 200 mm |
| BD-Q50040ER | 200 cm, 4 Fr, 5 mm x 40 mm |
| BD-Q50100ER | 200 cm, 4 Fr, 5 mm x 100 mm |
| BD-Q50150ER | 200 cm, 5 Fr, 5 mm x 150 mm |
| BD-Q50200ER | 200 cm, 5 Fr, 5 mm x 200 mm |
| BD-Q60040ER | 200 cm, 4 Fr, 6 mm x 40 mm |
| BD-Q60100ER | 200 cm, 5 Fr, 6 mm x 100 mm |
| BD-Q60150ER | 200 cm, 5 Fr, 6 mm x 150 mm |
| BD-Q60200ER | 200 cm, 5 Fr, 6 mm x 200 mm |
| BALLOON DIAMETER (mm) | BALLOON LENGTH (mm) | |||||||
| - | 20 | 40 | 60 | 80 | 100 | 120 | 150 | 200 |
| 2 | BD-F20020LW | BD-F20040LW | BD-F20060LW | BD-F20080LW | BD-F20100LW | BD-F20120LW | BD-F20150LW | BD-F20200LW |
| 2.5 | BD-F25020LW | BD-F25040LW | BD-F25060LW | BD-F25080LW | BD-F25100LW | BD-F25120LW | BD-F25150LW | BD-F25200LW |
| 3 | BD-F30020LW | BD-F30040LW | BD-F30060LW | BD-F30080LW | BD-F30100LW | BD-F30120LW | BD-F30150LW | BD-F30200LW |
| 4 | BD-F40020LW | BD-F40040LW | BD-F40060LW | BD-F40080LW | BD-F40100LW | BD-F40120LW | BD-F40150LW | BD-F40200LW |
| 5 | BD-F50020LW | BD-F50040LW | BD-F50060LW | BD-F50080LW | BD-F50100LW | - | - | - |
| 6 | BD-F60020LW | BD-F60040LW | - | - | - | - | - | - |
| BALLOON DIAMETER (mm) | BALLOON LENGTH (mm) | |||||
| 60 | 80 | 100 | 120 | 150 | 200 | |
| 5 | - | - | - | BD-F50120LW | BD-F50150LW | BD-F50200LW |
| 6 | BD-F60060LW | BD-F60080LW | BD-F60100LW | BD-F60120LW | BD-F60150LW | BD-F60200LW |
| BALLOON DIAMETER (mm) | BALLOON LENGTH (mm) | |||||||
| - | 20 | 40 | 60 | 80 | 100 | 120 | 150 | 200 |
| 2 | BD-F20020LR | BD-F20040LR | BD-F20060LR | BD-F20080LR | BD-F20100LR | BD-F20120LR | BD-F20150LR | BD-F20200LR |
| 2.5 | BD-F25020LR | BD-F25040LR | BD-F25060LR | BD-F25080LR | BD-F25100LR | BD-F25120LR | BD-F25150LR | BD-F25200LR |
| 3 | BD-F30020LR | BD-F30040LR | BD-F30060LR | BD-F30080LR | BD-F30100LR | BD-F30120LR | BD-F30150LR | BD-F30200LR |
| 4 | BD-F40020LR | BD-F40040LR | BD-F40060LR | BD-F40080LR | BD-F40100LR | BD-F40120LR | BD-F40150LR | BD-F40200LR |
| 5 | BD-F50020LR | BD-F50040LR | BD-F50060LR | BD-F50080LR | BD-F50100LR | - | - | - |
| 6 | BD-F60020LR | BD-F60040LR | - | - | - | - | - | - |
| BALLOON DIAMETER (mm) | BALLOON LENGTH (mm) | |||||||
| - | 20 | 40 | 60 | 80 | 100 | 120 | 150 | 200 |
| 5 | - | - | - | - | - | BD-F50120LR | BD-F50150LR | BD-F50200LR |
| 6 | - | - | BD-F60060LR | BD-F60080LR | BD-F60100LR | BD-F60120LR | BD-F60150LR | BD-F60200LR |
RX ONLY. Refer to the product labels and package inserts for complete warnings, precautions, potential complications, and instructions for use.
1. Data on File. Terumo Medical Corporation - R2P Crosstella RX
2. CROSSTELLA OTW IFU, SEPTEMBER 2021
3. Data on File. Terumo Medical Corporation - CROSSTELLA OTW product info
4. CROSSTELLA RX IFU, April 2021
5. Data on File. Terumo Medical Corporation - CROSSTELLA RX product info
6. R2P CROSSTELLA RX IFU, March 2019